Rooftop and ground-mounted solar arrays on a modern property at sunset
Home Solar Energy Saver

Solar Energy SaverGenerate it. Store it. Stop buying it.

Solar modules from 440 W to 800 W, hybrid and on-grid inverters from 3.5 kW to 60 kW, lithium storage from 4.8 kWh to 3.6 MWh, and complete 5–500 kW systems. Sized against your real consumption and roof, not a rule of thumb.

Modules 440–800 W · up to 24.8 % efficiency
On-grid, hybrid & off-grid, 5–500 kW
LFP storage 4.8 kWh – 3.6 MWh
Panels and everything behind them

Two halves of one system

A saving comes from the pair: a module that keeps producing in 25 years, and electronics that put every kilowatt-hour where it is worth most — into your load, then your battery, then the grid.

Bifacial double-glass solar module, front and rear view

Solar modules

Half-cell N-type modules in four cell technologies, so the roof decides the product rather than the other way round.

  • TOPCon bifacial 440–665 W, full-black options
  • HJT bifacial 715–735 W for large arrays
  • Back-contact (BC) 645–665 W where looks matter
  • Mono PERC 560–575 W as the budget line
  • 30-year performance warranty on N-type products
Hybrid solar inverters, wall mounted

Inverters, storage & complete systems

Off-grid, hybrid and on-grid electronics with matched lithium storage — supplied as a kit with cable, combiner boxes and mounting.

  • Single-phase 3.5–5.5 kW, three-phase 8–16 kW
  • Commercial 50–60 kW with 4 MPPT trackers
  • LFP racks 4.8–16 kWh, >6,000 cycles
  • Cabinet ESS 96–261 kWh, container ESS to 3.6 MWh
  • 5–500 kW packaged systems, on-grid or hybrid
Rack-mounted lithium iron phosphate batteries

Rack LFP batteries

4.8 – 16.07 kWh modules, 48 V and 51.2 V, up to 15 in parallel.

Outdoor cabinet energy storage system

Cabinet ESS

96 – 261 kWh outdoor IP54 cabinet, air or liquid cooled.

Container energy storage system

Container ESS

964 kWh – 3.6 MWh, 4–15 strings, RS485 / CAN / TCP-IP.

Bifacial double glass module

Bifacial double glass

Up to 95 % bifaciality — 4–21 % extra yield from the rear face.

The complete sheet

Every product we supply, side by side

Catalogue performance for each class in the range. The exact model, string layout and yield are confirmed against your roof, shading and consumption before order.

1 · Solar modules
Module seriesPower rangeModule efficiencyDimensions WeightCellsProduct / performance warrantyTypical use
HEX5 · BSM560–575M10-72HPHMono PERC, half-cell, monofacial560 – 575 W21.68 – 22.26 %2278 × 1134 × 30 mm28.4 kg144 (6×24)12 yr / 25 yr · ≤0.55 %/yrBudget line
HEX7 · BSM440–460M10-54HNHN-type TOPCon, bifacial, full black440 – 460 W22.02 – 23.02 %1762 × 1134 × 30 mm24.9 kg96 (6×16)12 yr / 30 yr · ≤0.4 %/yrSmall roofs
HEX7 · BSM510–530M10-60HNHN-type TOPCon, bifacial, full black510 – 530 W23.56 – 24.48 %1909 × 1134 × 30 mm25.5 kg120 (6×20)12 yr / 30 yr · ≤0.4 %/yrVillas
HEX7 · BSM595–615M10-72HNHN-type TOPCon, bifacial595 – 615 W23.03 – 23.81 %2278 × 1134 × 30 mm31.5 kg144 (6×24)12 yr / 30 yr · ≤0.4 %/yrRoof & ground
HEX7 · BSM645–665G12-60HNHN-type TOPCon, bifacial645 – 665 W23.88 – 24.62 %2382 × 1134 × 30 mm31.75 kg132 (6×22)12 yr / 30 yr · ≤0.4 %/yrCommercial
HEX9 · BSM715–735G12-66HNHN-type HJT, bifacial, 210 mm715 – 735 W23.02 – 23.70 %2384 × 1303 × 33 mm36.6 kg132 (6×22)12 yr / 30 yr · ≤0.375 %/yrUtility scale
HPBC 2.0 · BSM645–665M10-72HJDBack-contact (BC), bifacial645 – 665 W23.90 – 24.60 %2382 × 1134 × 30 mm32.3 kg144 (6×24)15 yr / 30 yr · ≤0.35 %/yrAesthetics
JAM144D 605–640NN-type 182 mm, bifacial double glass605 – 640 Wup to 24.80 %2278 × 1134 × 35/30 mm31.8 kg144 (72×2)Per supplier statementMax W/m²
JAM132D 635–670WN-type, bifacial double glass, 16/18BB635 – 670 Wup to 24.68 %2382 × 1134 × 30/35 mm32.4 kg132 (66×2)Per supplier statementCommercial
JAM132D 770–800WN-type 210 mm half-cut, bifaciality ≤95 %770 – 800 Wup to 24.39 %2384 × 1303 × 33/35 mm38.5 kg132 (66×2)Per supplier statementGround-mount

All modules: STC 1000 W/m², cell 25 °C, AM1.5. Operating −40 °C to +85 °C, 1000/1500 V DC system voltage, snow load 5400 Pa and wind load 2400 Pa, IP68 junction box with 3 bypass diodes, anodised aluminium frame, MC4 / MC4-EVO2 connectors. Bifacial gain depends on ground albedo and mounting height (typically 4–8 % over grass, 15–21 % over snow or white surfaces).

2 · Inverters
ModelRated outputPeak powerOutput voltage Battery voltagePV / waveformMotor loadWeight & size
HSI 3.5 kWOff-grid / hybrid, wall mount3,500 W6,000 VA230 V single-phase24 V · 20–33 Vdc80 A PV charge2 HP7.4 kg378×280×103 mm
HSI 5.5 kWUp to 6 units in parallel5,500 W11,000 VA230 V single-phase48 V · 40–60 Vdc100 A PV charge4 HP10.5 kg426×322×124 mm
SPI-8K-EUHybrid, EU IEC approvals8,000 W16,000 W230/400 V three-phase48 V · 40–60 VdcPure sine, 10 ms switch5 HP27 kg620×445×130 mm
SPI-10K-EU10,000 W20,000 W230/400 V three-phase48 V · 40–60 VdcPure sine, 10 ms switch6 HP27 kg620×445×130 mm
SPI-12K-EU12,000 W24,000 W230/400 V three-phase48 V · 40–60 VdcPure sine, 10 ms switch6 HP27 kg620×445×130 mm
WGS-16KP2-SROL-EULi-ion BMS with dual activation16,000 W2 × rated for 10 s230/400 V three-phase48 V · 40–60 VdcPure sine, 10 ms switch9 HP47.5 kg593×803×215 mm
IESP 50 kW4 independent MPPT trackers50,000 W60,000 VA220/380 – 230/400 V (3L+N+PE)150 – 850 V · 2×80 A100 kW max PV21 HP98 kg622×342×1010 mm
IESP 55 kW55,000 W60,500 VA220/380 – 230/400 V150 – 850 V · 2×80 A110 kW max PV23 HP98 kg622×342×1010 mm
IESP 60 kW60,000 W66,000 VA220/380 – 230/400 V150 – 850 V · 2×80 A120 kW max PV25 HP98 kg622×342×1010 mm

Hybrid models run PV, battery and grid together and switch to battery in about 10 ms, so freezers, tills and pumps do not notice an outage. The 50–60 kW class carries four independent MPPT trackers and accepts unbalanced three-phase load.

3 · Batteries & energy storage
ProductVoltageUsable capacityCycle life Working range / cellDimensionsWeightScaling
RY-100480 / RY-100512Rack-mounted LFP, 100 Ah48 V / 51.2 V4.8 / 5.12 kWh>6,000 cycles40.4–54 V / 43.2–57.6 V430×482×178 mm39 / 41 kg15 units parallel
RY-200480 / RY-200512Rack-mounted LFP, 200 Ah48 V / 51.2 V9.6 / 10.24 kWh>6,000 cycles40.4–54 V / 43.2–57.6 V790×482×178 mm94 / 98 kg15 units parallel
WY-100512 / WY-200512Wall or floor LFP51.2 V5.12 / 10.24 kWh>6,000 cycles43.2–57.6 Vdc540×460×200 /
790×530×200 mm
44 / 87 kg15 units parallel
WY-314512314 Ah high-capacity LFP51.2 V16.07 kWh>6,000 cycles43.2–57.6 Vdc850×550×250 mm130 kg15 units parallel
6-JFM(G)-100Ah / 200AhSealed gel lead-acid12 V1.2 / 2.4 kWhCyclic 14.4–14.9 VFloat 13.6–13.8 V330×173×217 /
522×240×219 mm
25 / 50 A chargeBackup & pumping
JS-ESS261HOutdoor cabinet ESS, IP54832 V (728–736 V)96 – 261 kWh≥6,000 cyclesLFP 3.2 V / 314 Ah · 1P52S×50.5 C dischargeAir or liquid cooling4G / CAN / RS485
Container ESSModular 20 ft container768 V strings964.6 – 3,617.2 kWh≥6,000 cycles51.2 V 314 Ah · 15 pcs/string4 – 15 stringsLiquid or air coolingRS485 / CAN / TCP-IP

Lithium products are LFP (lithium iron phosphate) with integrated BMS, IP20 or IP65 enclosures, and rack, wall or floor mounting. Cabinet and container systems are quoted per project with the PCS, transformer and cooling selected to the load profile.

4 · Complete PV systems
SystemPV arrayInverterAC connection DC cable includedMC4 connectorsMounting
JAM-5KW-ON / JAM-5KW-HYOn-grid or hybrid with storage5 kW5 kW230 V single-phase100 m6 pairsRoof / ground / carport
JAM-10KW-ON / JAM-10KW-HYOn-grid or hybrid with storage10 kW10 kW230 V single-phase200 m12 pairsRoof / ground / carport
JAM-20KW-ON / JAM-20KW-HYOn-grid or hybrid with storage20 kW20 kW400 V three-phase400 m24 pairsRoof / ground / carport
JAM-50KW-ON / JAM-50KW-HYOn-grid or hybrid with storage50 kW50 kW400 V three-phase1,000 m60 pairsRoof / ground / carport
JAM-100KW-ON / JAM-100KW-HYOn-grid or hybrid with storage100 kW100 kW400 V three-phase2,000 m120 pairsRoof / ground / carport
JAM-150KW-ON / JAM-150KW-HYOn-grid or hybrid with storage150 kW150 kW400 V three-phase3,000 m180 pairsRoof / ground / carport
JAM-500KW-ON / JAM-500KW-HYOn-grid or hybrid with storage500 kW500 kW400 V three-phase10,000 m600 pairsGround / carport

Each packaged system ships with modules, inverter, PV combiner box, DC and AC cable, MC4 connectors and the mounting structure. Hybrid versions add lead-acid or lithium storage. US variants (120 V single-phase / 208–480 V three-phase) are available on request.

Rough sizing

What size does a building like yours need?

A real figure comes from twelve months of bills plus a roof survey. These are the bands we see most often, as a starting point for the conversation.

3–6 kW

Apartment or small house

6–11 modules, single-phase hybrid inverter, 5–10 kWh battery. Covers lighting, appliances and hot water.

8–15 kW

Villa or large family home

15–25 modules, three-phase hybrid, 10–20 kWh storage. Runs air conditioning and an EV charger.

30–100 kW

Commercial premises

Warehouse, hotel or workshop roof. Daytime load matched first, storage sized for the evening peak.

100 kW +

Industrial & ground-mount

Bifacial 665–800 W modules, 50–60 kW inverter blocks, cabinet or container ESS up to 3.6 MWh.

Also on the truck

The parts that quietly decide the yield

Mounting & structureRoof, ground and carport structures, made to the pitch, span and wind zone of the site.
Combiner boxes & cable2-in-1 and 6-in-6-out DC combiner boxes, 1500 V PV cable in 4 mm² and 6 mm², MC4 connectors.
Solar water pumps3" and 4" AC/DC submersible pumps 750–2200 W to 250 m head, plus DC booster pumps for irrigation.
Solar street lighting4, 6, 10 and 15 m galvanised Q235 poles with integrated PV lamp heads and ground cages.
Cleaning equipmentTwin-disc telescopic brushes and a track-type cleaning robot — dust costs more yield than most people expect.
Monitoring4G, CAN and RS485 monitoring on the storage systems; remote monitoring on the hybrid inverter range.
How it runs

From enquiry to commissioning

01

Consumption & roof survey

Twelve months of bills, load profile, roof area, pitch, orientation and shading measured on site.

02

System design

Module and inverter selection, string layout, battery sizing, cable and protection — issued as a written specification with a yield estimate.

03

Supply & installation

Structure, modules, electronics and storage delivered together and installed by our own crews.

04

Commissioning & monitoring

Tested, grid application completed, monitoring set up, and handed over with a service interval.

Questions

The ones we get asked most

TOPCon, HJT or back-contact — which should I buy?

TOPCon is the default: 23–24.6 % efficiency, a 30-year performance warranty and the best price per watt. HJT holds output better on very hot roofs and comes in the largest formats (715–735 W), so it suits big ground-mounted arrays. Back-contact has no front busbars, which gives a uniform black surface, better low-angle capture and roughly 24.6 % efficiency — the choice when the array is visible from the street.

What does bifacial actually add?

A bifacial module also collects light reflected onto its rear face. Over grass expect 4–8 %, over sand 8–12 %, over snow or a white-painted roof 15–21 %. It needs clearance under the module and a reflective surface — on a dark flat roof with the panels laid low, the gain is close to zero, so we only quote it where the mounting supports it.

On-grid or hybrid with a battery?

On-grid is the cheapest per kilowatt-hour and pays back fastest where export is credited. Hybrid adds a battery and rides through outages, which matters for cold storage, hospitality and anywhere the supply is unreliable. The electronics are sized the same way; the battery is sized from the evening load, not the roof.

How long do the products stay under warranty?

N-type modules carry a 12-year product warranty (15 years on back-contact) and a 30-year linear performance warranty with annual degradation capped at 0.35–0.4 %. The mono PERC line carries 12 years product and 25 years performance at 0.55 % a year. Lithium storage is rated above 6,000 cycles.

Do you supply only, or install as well?

Both. We supply developers, contractors and specifiers from container quantities, and we install complete systems — structure, modules, electronics, storage and grid application — with our own crews.

Get started

Free site survey, fixed quote, no pressure

Send us a recent electricity bill and a photo of the roof. You will get an itemised specification with the module and inverter models named, an annual yield estimate and a payback figure — not a discounted headline price.

No obligation and no deposit to book
Itemised specification with named models
One team for glazing and solar

Request your free quote

Send us the opening sizes or your drawings — we come back with a specification and a written quotation.

Or write to us directly on WhatsApp. WhatsApp →